| Not all decoders have CV Reset.
For those that do, CV Reset is handled completely by the decoder and
is non-intrusive - you do not need to bother with it unless you want
to use it. The only thing necessary to make it work is a system or
other method that can program CV30 - with one exception mentioned
below.
With SoundTraxx decoders, programming
a "02" into CV30 while in the service programming mode
will prime it to reset all CVs back to factory default. With this
done, all CVs will be reset to factory default when track power is
restored.
With Train Control Systems decoders,
programming a "02" into CV30, or into Physical Register
#8 for systems that can't program CV 30, will prime the decoder to
reset all CVs except for the User-Loadable Speed Table. Doing this
in the service programming mode will insure that power is cycled off
and back on to complete the reset process when track power is restored.
Neither Digitrax nor NCE decoders
have CV Reset. Many other manufacturers also do not have CV Reset.
All Digitrax systems can access
CV Reset if needed.
|